Wiser-Thermostat
Click once on thermostat - sync with controller about current temperature setpoint and update ambient temperature to actuator
Source | Destination | Payload | action | ep | cluster | attribute | data type | value |
---|---|---|---|---|---|---|---|---|
Thermostat | Controler | report ambient temperature | report attribute | 11 | 0x0402 | 0x0000 | 0x29 | temp*100 |
Thermostat | Actuator | report ambient temperature | report attribute | 11 | 0x0402 | 0x0000 | 0x29 | temp*100 |
Actuator | Controler | report ambient temperature | report attribute | 11 | 0x0402 | 0x0000 | 0x29 | temp*100 |
Thermostat | Actuator | ask for setpoint | read attribute | 11 | 0x0201 | 0x0012 | ||
Actuator | Thermostat | answer setpoint | read attribute | 11 | 0x0201 | 0x0012 | 0x29 | temp*100 |
Actuator | Controler | ask for setpoint | read attribute | 11 | 0x0201 | 0x0012 | ||
Controler | Actuator | answer setpoint | read attribute | 11 | 0x0201 | 0x0012 | 0x29 | temp*100 |
Thermostat | Actuator | ask for mode | read attribute | 11 | 0x0201 | 0xe010 | ||
Actuator | Thermostat | asnwer mode | read attribute | 11 | 0x0201 | 0xe010 | 0x30 | mode |
Actuator | Controler | ask for mode | read attribute | 11 | 0x0201 | 0xe010 | ||
Controler | Actuator | answer mode | read attribute | 11 | 0x0201 | 0xe010 | 0x30 | mode |
Thermostat | Actuator | ask for maxHeatingsetpoint | read attribute | 11 | 0x0201 | 0x0016 | ||
Actuator | Thermostat | answer maxHeatingsetpoint | read attribute | 11 | 0x0201 | 0x0016 | 0x29 | temp*100 |
Actuator | Controler | ask for maxHeatingsetpoint | read attribute | 11 | 0x0201 | 0x0016 | ||
Controler | Actuator | answer maxHeatingsetpoint | read attribute | 11 | 0x0201 | 0x0016 | 0x29 | temp*100 |
Thermostat | Actuator | ask for minHeatingsetpoint | read attribute | 11 | 0x0201 | 0x0015 | ||
Actuator | Thermostat | answer minHeatingsetpoint | read attribute | 11 | 0x0201 | 0x0016 | 0x29 | temp*100 |
Actuator | Controler | ask for minHeatingsetpoint | read attribute | 11 | 0x0201 | 0x0015 | ||
Controler | Actuator | answer minHeatingsetpoint | read attribute | 11 | 0x0201 | 0x0016 | 0x29 | temp*100 |
Click on + on the thermostat (increase setpoint temperature by 0.5 degree)
Source | Destination | Payload | action | ep | cluster | command | value |
---|---|---|---|---|---|---|---|
Thermostat | Actuator | setpoint temperature | command set temp | 11 | 0x0201 | 0xe0 | 0x00 + zone + temp*100+ 0xFF |
Actuator | Controler | setpoint temperature | command set temp | 11 | 0x0201 | 0xe0 | 0x00 + zone + temp*100+ 0xFF |
Controler | Actuator | setpoint temperature | command set temp | 11 | 0x0201 | 0xe0 | 0x00 + zone + temp*100+ 0xFF |
Thermostat setpoint from hub
Source | Destination | Payload | action | ep | cluster | command | value |
---|---|---|---|---|---|---|---|
Controler | Actuator | setpoint temperature | command set temp | 11 | 0x0201 | 0xe0 | 0x00 + zone + temp*100+ 0xFF |