ZigBeeForDomoticZ plugin Wiki

Wiser-Thermostat

Click once on thermostat - sync with controller about current temperature setpoint and update ambient temperature to actuator

Source Destination Payload action ep cluster attribute data type value
Thermostat Controler report ambient temperature report attribute 11 0x0402 0x0000 0x29 temp*100
Thermostat Actuator report ambient temperature report attribute 11 0x0402 0x0000 0x29 temp*100
Actuator Controler report ambient temperature report attribute 11 0x0402 0x0000 0x29 temp*100
                 
Thermostat Actuator ask for setpoint read attribute 11 0x0201 0x0012    
Actuator Thermostat answer setpoint read attribute 11 0x0201 0x0012 0x29 temp*100
Actuator Controler ask for setpoint read attribute 11 0x0201 0x0012    
Controler Actuator answer setpoint read attribute 11 0x0201 0x0012 0x29 temp*100
                 
Thermostat Actuator ask for mode read attribute 11 0x0201 0xe010    
Actuator Thermostat asnwer mode read attribute 11 0x0201 0xe010 0x30 mode
Actuator Controler ask for mode read attribute 11 0x0201 0xe010    
Controler Actuator answer mode read attribute 11 0x0201 0xe010 0x30 mode
                 
Thermostat Actuator ask for maxHeatingsetpoint read attribute 11 0x0201 0x0016    
Actuator Thermostat answer maxHeatingsetpoint read attribute 11 0x0201 0x0016 0x29 temp*100
Actuator Controler ask for maxHeatingsetpoint read attribute 11 0x0201 0x0016    
Controler Actuator answer maxHeatingsetpoint read attribute 11 0x0201 0x0016 0x29 temp*100
                 
Thermostat Actuator ask for minHeatingsetpoint read attribute 11 0x0201 0x0015    
Actuator Thermostat answer minHeatingsetpoint read attribute 11 0x0201 0x0016 0x29 temp*100
Actuator Controler ask for minHeatingsetpoint read attribute 11 0x0201 0x0015    
Controler Actuator answer minHeatingsetpoint read attribute 11 0x0201 0x0016 0x29 temp*100

Click on + on the thermostat (increase setpoint temperature by 0.5 degree)

Source Destination Payload action ep cluster command value
Thermostat Actuator setpoint temperature command set temp 11 0x0201 0xe0 0x00 + zone + temp*100+ 0xFF
Actuator Controler setpoint temperature command set temp 11 0x0201 0xe0 0x00 + zone + temp*100+ 0xFF
Controler Actuator setpoint temperature command set temp 11 0x0201 0xe0 0x00 + zone + temp*100+ 0xFF

Thermostat setpoint from hub

Source Destination Payload action ep cluster command value
Controler Actuator setpoint temperature command set temp 11 0x0201 0xe0 0x00 + zone + temp*100+ 0xFF