Salus Corner
Overview
Devices
Salus Thermostat
Decoding sequence
Hub |
direction |
Devices |
Value |
|
<- |
Match Descriptor Request |
|
|
<- |
Read Attributes |
|
|
<- |
Device Announcement |
|
Match Descriptor response |
-> |
|
0x01 |
Read Attribute response |
-> |
|
SAU2AG1 |
Active Endpoint Request |
-> |
|
|
|
<- |
Active Ep response |
0x09 |
Identify |
-> |
|
0x00 |
Read Attribute |
-> |
|
0x0000 / 0x0005 |
|
<- |
Read Attr Response |
SAL6ET1 |
|
<- |
Command 0x10 |
Cluster: 0xfc00, FCF: 0x1d, ManufCode: 0x1078, Data: ff0202a4509a00 |
Command 0x81 |
-> |
|
Data: 2000c244c325030e00ffffffff3100 |
|
<- |
Command 0x31 |
Data: 21204a20303030302a4a46422a664b573f6320203d502c4b573f6320203d502c4b573f6320203d502c4b573f6320203d502c4b573f6320203d502c51573f63202039502c51573f63202039502c |
|
<- |
Command 0x31 |
Data: 212e4a4a30303030202020213030303035273030342a312a312e31662a56342c202020202020202020202020202020202020202020202020314a4a30ffcd000001004a21202020450900656520 |
Read Attribute |
-> |
|
0x0000 / 0x0003, 0x0005 |
|
<- |
Read Attr Response |
0x0003: 0xff, 0x0005: SAL6ET1 |
Loop of communication between Thermostat and Hub
Hub |
direction |
Devices |
Value |
|
<- |
Command 0x17 |
Data: 34083408f40101 |
|
<- |
Command 0x8e |
Data: 0146d2ffffffffffffffffffffffff |
|
<- |
Command 0x31 |
Data: 212e4a4a30303030202020213030303035273030342a312a312e31662a56342c202020202020202020202020202020202020202020202020314a4a30ff00000002004a21202020451300656520 |