How to prepare the plugin for Schneider Wiser devices. See Schneider Wiser for the devices and their protocol notes.
Schneider has two Wiser families, which need a different setup:
| Family | Devices (Zigbee models) | IEEE starts with |
|---|---|---|
| Legacy Wiser | Thermostat EH-ZB-RTS, radiator valve EH-ZB-VACT, actuators EH-ZB-HACT / EH-ZB-LMACT, smart plugs EH-ZB-SPD / EH-ZB-SPD-V2, energy meter EH-ZB-BMS |
00124b |
| Wiser Home and other recent Schneider devices | Thermostat CCTFR6400 (Wiser2-Thermostat), radiator valve CCTFR6100 (iTRV), micromodules (PUCK…), shutter switches, socket outlets… |
588e81 and others |
The recent devices are standard Zigbee 3.0 devices: pair them as usual (see Add a new device). If the Wiser Home thermostat doesn’t talk to the plugin, enable the Wiser2 setting (see below).
The legacy Wiser devices only work on a network with a specific extended PAN ID, and with the settings below.
All these settings are in the WebUI Settings page, with Advanced settings switched on (see WebUI Settings).
| Setting | Section | Value | Why |
|---|---|---|---|
enableSchneiderWiser |
Pairing settings | on | The plugin asks the legacy Wiser devices for their model during pairing. |
Wiser |
Zigpy CIE specific configuration (zigpy coordinators) | on | Adds the endpoint 0x0b the legacy Wiser devices talk to. Needs a plugin restart. |
extendedPANID |
Coordinator settings | xxxx484504015e10 |
The legacy Wiser devices only join a network whose extended PAN ID ends with 484504015e10. Replace xxxx with any 4 hexadecimal digits, for example 2141484504015e10. |
For a Wiser Home thermostat (CCTFR6400) that doesn’t communicate, enable Wiser2 in Zigpy CIE specific configuration instead: it adds the endpoint 0x03 used by these devices.
The extended PAN ID is only applied when the coordinator forms a new network. Changing it erases the network: all the devices already paired must be paired again, whatever their brand. The other brands (Ikea, Philips, Xiaomi, Tuya…) work fine on a network with a Wiser extended PAN ID, so if you plan to use legacy Wiser devices, set it before pairing anything.
extendedPANID (and the other settings above) and click Validate.autoRestore setting off (Zigpy CIE specific configuration, advanced): otherwise the plugin restores the last coordinator backup, with the old extended PAN ID, instead of forming a new network.autoRestore back on.The legacy Wiser devices were tested on channels 11, 15 and 25. See Change the Zigbee channel.
Some Wiser devices have device parameters (room number, lock, open-window detection, shutter travel time…): see Device parameters.