When the Shutter leave the network, it searches for an open network
The pairing process is well documented on Zigate.fr
Reset of Shutter and Remote command
Remote will flash RED then GREEN
You can check that the remote command the shutter. In case not, please consult the Profalux documentation
Pairing of Shutter
Switch Coordinator to pairing mode ( Permit to Join, or use the Provisionning function from Web Admin) Any Shutter part of the network will do an Up/Down
Press once on R (back side of remote) The remote Led should blink Once. (if the remote doesn’t blink the request as not been taken)
Press UP
The shutter should go up-down The Shutter and the Remote will go out of the Zigbee network, and search for an open (pairing) network.
All Shutter and the one you want to add are doing an Up/Down, which confirm the correct pairing
When the remote Led do not flash anymore press STOP This will close the network and complete the pairing of a new Shutter
Profalux do not use attribut 0x0005 Model Name of Basic cluster. Attribut 0x0010 of Basic Cluster should provide Type of device ( ‘bso’, volet’ )
When you don’t have any controler, one of the shutter act as a controler
Interestingly, you can move the network from one Channel to an other one via the ZOE Admin menu
ProfileID 0104
ZDeviceID 0201
Application Version 0000
Cluster IN Count: 03
Cluster In 1: 0000 (Basic)
Cluster In 2: 0003 (Identify)
Cluster In 3: 0015 (Commissioning)
Cluster OUT Count: 08
Cluster Out 1: 0003 (Identify)
Cluster Out 2: 0004 (Groups)
Cluster Out 3: 0005 (Scenes)
Cluster Out 4: 0006 (On/Off)
Cluster Out 5: 0008 (Level Control)
Cluster Out 6: 0100 (Shade Configuration)
Cluster Out 7: fc20
Cluster Out 8: fc21
The Profalux shutter can be steer with cluster ONOFF (0x0006) or cluster LevelControl (0x0008). It is adviced to use only the LevelControl even for a full Open or Close.
Configure Reporting can be set on Cluster LevelControl (0x0008) attribute (0x0000)
The remote is very basic and it is not adviced to try doing anything with it. During the pairing process, the Shutter and the Remote will announced themselve, just drop the remote, but keep it paired on Coordinator as both VR and Remote must be part of the same network.
Never try to bind the remote with the Coordinator
If you have a ZOE central remote, you can create groups, and those groupes are created in the range of 0x8000 - 0x8… ) Otherwise , Profalux informed me that depending on the Firmware version of Zoe, they must be pgraded before been paired with a non-Profalux controler. For that the best is to contact Profalux for getting the upgrade.