ZigBeeForDomoticZ plugin Wiki

Purpose is to document all findings around Profalux Zigbee blind/shutter

Profalux behaviour

When the Shutter leave the network, it searches for an open network

Pairing Process

The pairing process is well documented on Zigate.fr

Findings

Profalux do not use attribut 0x0005 Model Name of Basic cluster. Attribut 0x0010 of Basic Cluster should provide Type of device ( ‘bso’, volet’ )

When you don’t have any controler, one of the shutter act as a controler

Interestingly, you can move the network from one Channel to an other one via the ZOE Admin menu

VR

ProfileID 0104
ZDeviceID 0201
Application Version 0000
Cluster IN Count: 03
Cluster In 1: 0000 (Basic)
Cluster In 2: 0003 (Identify)
Cluster In 3: 0015 (Commissioning)
Cluster OUT Count: 08
Cluster Out 1: 0003 (Identify)
Cluster Out 2: 0004 (Groups)
Cluster Out 3: 0005 (Scenes)
Cluster Out 4: 0006 (On/Off)
Cluster Out 5: 0008 (Level Control)
Cluster Out 6: 0100 (Shade Configuration)
Cluster Out 7: fc20
Cluster Out 8: fc21

BSO

Store

Steering and other findings

References: