Acces to the WebUI: http://<yourdomoticzIP>:9440
After pairing you should see the devices in the Domoticz Settings devices. There you should see the paired devices.
Next thing to do pair the bulb and the MS. This can be done by
When finished the red light in the MS will switch and the bulb will flash and the WO will make a clicking sound or the led will flash.
After some time the new group will be added to the devices tab in Setting.
Check the unused devices for a Zigate group.
Whenever movement is detected by the MS will trigger the bulb or WO to switch on. The Status of the bulb, WO and the MS widget change. Depending on the settings on the MS it will switch of after after the set time.
The MS can be made standalone by deleting the devices in the group in the groupmanagement page. After validating and restarting the plugin the group will still exist without any devices. The motion sensor is connected to this group in the background. Status changes can be seen in the domoticz log and in the MS Widget.
Now it is possible to use the MS in a script (LUA, Dzvent or Blockly). This way you are not bound to Zigbee products and you can use it with other devices who run on other protocols like (Zwave, wifi, mqtt or 433mhz).
When using tradfri devices like the Ikea 5 button round remote or the Ikea motion sensor the created widgets are not active after pairing. After paring the device widgets are added to DomoticZ but actions can not be seen in DomoticZ. There you to add those devices to a group. See Corner_Ikea-Remote To make them active go to webUI management Group management and fill the checkmark behind the group where the remote or motion sensor is part of, to make active. After validating, a group rescan and plugin restart the remote or motion sensor will be active. This way you get statusupdate in the widgets and the remote will be capable of using the left and right button.
This activation of tradfri devices is limited to 5 devices. This is because of limited memoryspace in the Zigatechip. When you add a Zigate to a group for the sixth time the device connection is not established. You get a this error in the domoticz log: We reach the max number of Cycle and didn’t succeed in the Group Creation.